DTC P1132 - Lambda Bank 1 Sensor 1 Above Maximum Threshold

Conditions for setting dtc P1132

Engine Running
Lambda Bank 1 Sensor 1 ≥ 12.0
The above must be present for a period of 128 instances/cycles or greater to trigger DTC P1132