GM > Transmission Diagnostics
P1870 Transmission Component Slipping
- Min Trans Temp: Minimum transmission temp for P1870 error testing.
- Max Trans Temp: Maximum transmission temp for P1870 error testing.
- Set Max Slip RPM:
- Set Min Slip RPM:
- Clear Max Slip RPM:
- Clear Min Slip RPM:
Trans overtemp
- Set Temp: The minimum trans temp required to set an overtemp condition.
- Set Time: The minimum time required to set an overtemp conation once the overtemp qualification is met.
- Clear Temp: The minimum trans temp required to clear an overtemp condition.
- Clear Time: The minimum time required to clear an overtemp conation once the Clear Temp qualification is met.
Invalid Torque Signal
- Freeze Adapts If enabled the transmission will freeze all adapt cells if the invalid torque signal is received from the ECM.
- Max Pressure If enabled the transmission will command full line pressure if the invalid torque signal is received from the ECM.
- Torque Management Inhibit If enabled the transmission will inhibit torque management if the invalid torque signal is received from the ECM.
- Pressure Override If enabled the transmission will use the default pressure table (TPS based) if the invalid torque signal is received from the ECM.